LOINCActiveBoth

LOINC Code 78973-5: CT scanogram Lower extremity - bilateral for leg measurement WO contrast

78973-5 is a LOINC code used to identify CT scanogram Lower extremity - bilateral for leg measurement WO contrast in laboratory and clinical observation data. You may see this code in lab systems, lab reports, EHR exports, interoperability feeds, or other structured clinical data exchanges. LOINC codes identify tests, measurements, observations, survey items, and clinical questions in a standardized way. It is associated with the component Multisection for leg measurement^WO contrast. It is commonly used with the system or sample type Lower extremity.bilateral.

Reviewed by HealthAssure Clinical TeamUpdated 21 May 2026

What is this code?

LOINC codes identify tests, measurements, observations, survey items, and clinical questions in a standardized way. It is associated with the component Multisection for leg measurement^WO contrast. It is commonly used with the system or sample type Lower extremity.bilateral.

When is it used?

  • Used in lab systems, EHRs, and clinical data exchange.
  • May identify a test, observation, survey item, or clinical document request rather than a diagnosis.
  • Status: ACTIVE
  • Order vs observation: Both
  • Method: CT.scanogram

What it does not mean

  • The code identifies the observation or test, not the actual result.

Key facts

  • CT scanogram Lower extremity - bilateral for leg measurement WO contrast
  • Multisection for leg measurement^WO contrast
  • A computed tomography (CT) scanogram is a low-dose, non-contrast radiation imaging modality used for a variety of indications, including ante version, femur length and tibial length. A CT scanogram can be used for leg measurement when there are flexion contractures that would distort anteroposterior images, and when lateral images from a CT can provide bone leg measurement in patients with leg inequalities (e.g., ununited fracture). CT measurements of anteversion are based on the angle of rotation of the femoral neck relative to the femoral condyles and are used to determine whether there are rotational components, not simply a discrepancy in leg length.
  • Bil; Bilat; Both; c; CAT scan; Computed tomography; Computerized tomography; Contr; Contra; Contrst; CorePlaybook; CT scan; CT Scanogram; Document; EXT; Extr-Bl; Finding; Findings; Imaging; LE; LE-Bl; Leg; Low; Lower extremity; Playbook; Point in time; Rad; Radiology; Random; Scanogram; without contrast

Where you may see this code

You may see this code in lab systems, lab reports, EHR exports, interoperability feeds, or other structured clinical data exchanges.

Common synonyms

CT scanogram Lower extremity - bilateral for leg measurement WO contrastCT.scanogram LE-Bl leg meas WO contrMultisection for leg measurement^WO contrastRADFindPtLower extremity.bilateral

Frequently asked questions

Code details

Code78973-5
SystemLOINC
Display nameCT scanogram Lower extremity - bilateral for leg measurement WO contrast
DescriptionMultisection for leg measurement^WO contrast
Short nameCT.scanogram LE-Bl leg meas WO contr
ComponentMultisection for leg measurement^WO contrast
PropertyFind
TimingPt
System (specimen)Lower extremity.bilateral
ScaleDoc
MethodCT.scanogram
ClassRAD
StatusACTIVE
Order/ObservationBoth

Flags

BillableNo
Valid clinical useNo

Source

SourceLOINC
Version2.82
Releasemain
First released2.54
Last changed2.61

Part names

Multisection for leg measurement^WO contrastFindPtLower extremity.bilateralDocCT.scanogramBilateralTrueLower extremityCTContrastWOLeg measurementScanogramFindingPoint in time (spot)Lower extremity BilateralComputed tomography scanogram

About this content

This page is prepared by HealthAssure's clinical team using official coding standards from LOINC. AI tools assist with drafting explanations, which are then reviewed and verified by healthcare professionals for accuracy. This content is for informational purposes and does not replace professional medical advice. Meet our team.