24337-8 is a LOINC code used to identify Gas panel (BldC) in laboratory and clinical observation data. You may see this code in lab systems, lab reports, EHR exports, interoperability feeds, or other structured clinical data exchanges. LOINC codes identify tests, measurements, observations, survey items, and clinical questions in a standardized way. It is associated with the component Gas panel. It is commonly used with the system or sample type BldC.
LOINC codes identify tests, measurements, observations, survey items, and clinical questions in a standardized way. It is associated with the component Gas panel. It is commonly used with the system or sample type BldC.
When is it used?
Used in lab systems, EHRs, and clinical data exchange.
May identify a test, observation, survey item, or clinical document request rather than a diagnosis.
Status: ACTIVE
Order vs observation: Order
Panel type: Panel
What it does not mean
The code identifies the observation or test, not the actual result.
Key facts
Gas panel - Capillary blood
Gas panel
Knowing the concentration of inspired O2 is important to the interpretation of PO2 results. Inspired O2 can be recorded in two ways- as percent- of O2 delivered to the patient (Venturi mask, re-breather mask, or ventilator) or as liters of oxygen per minute (nasal canula). This panel includes terms for recording the inspired O2 in either fashion. But because only one will apply and labs do not always receive this information they are designated as optional. The term "oxygen saturation" is often used to refer to two distinctly different quantities, hemoglobin oxygen saturation (recommended symbol = sO2) and fractional oxyhemoglobin (recommended symbol = FO2Hb). The former is sometimes called functional oxygen saturation and the later, fractional oxygen saturation Hemoglobin oxygen saturation = is the amount of oxyhemoglobin expressed as the percent of the hemoglobin able to bind oxygen, i.e. oxyhemoglobin (O2Hb) + deoxyhemoglobin (HHb). sO2 = 100 x O2Hb/ (O2Hb + HHb) Fractional oxyhemoglobin = the amount of oxyhemoglobin expressed as a percent of the total hemoglobin, where tHb = O2Hb + HHb + [COHb + MetHb + SulfHb]. Note that COHb, MetHb, and SulfHb, cannot carry oxygen and are thus called dyshemoglobins. FO2Hb = O2Hb/tHb Gas machines that can measure carbon monoxide, could, in principle, also report FO2Hb, and we had assumed that they would. However, at least some machines that do measure COHb and MetHb provide no option for reporting FO2Hb, and report only sO2. When mapping blood gas panels that report COHb% and also report FO2Hb, map that term to the LOINC term with the component of "Oxyhemoglobin /Total hemoglobin". If such an instrument reports only "oxygen saturation, verify with the lab that they are really reporting a functional O2 sat and not the Fractional Oxyhemoglobin, because the two are not always correctly labeled. If it is sO2 then map it to the LOINC term with a component of "Oxygen saturation". When you are mapping data from a simpler Blood gas instrument (one that can read fewer than 4 wave lengths), then the O2 saturation will likely be a sO2. So map also moat that variable to the LOINC with a component of "Oxygen Saturation". (SourceMcD derived from Gill and McD- 2009 09)
BGas; Blood - capillary; Blood gas; Blood gases; Cap bld; Cap blood; Capillary bld; Capillary blood; Chemistry; Finger stick; Gas Pnl; Gases; Pan; PANEL.CHEMISTRY; Panl; Pnl; Point in time; QNT; Quan; Quant; Quantitative; Random
Where you may see this code
You may see this code in lab systems, lab reports, EHR exports, interoperability feeds, or other structured clinical data exchanges.
Gas panel-PtBldCQnPoint in time (spot)Blood capillary
About this content
This page is prepared by HealthAssure's clinical team using official coding standards from LOINC. AI tools assist with drafting explanations, which are then reviewed and verified by healthcare professionals for accuracy. This content is for informational purposes and does not replace professional medical advice. Meet our team.