LOINC Code 75264-2: Blood group antibody screen LISS Ql
75264-2 is a LOINC code used to identify Blood group antibody screen LISS Ql in laboratory and clinical observation data. You may see this code in lab systems, lab reports, EHR exports, interoperability feeds, or other structured clinical data exchanges. LOINC codes identify tests, measurements, observations, survey items, and clinical questions in a standardized way. It is associated with the component Blood group antibody. It is commonly used with the system or sample type Ser/Plas.
What is this code?
LOINC codes identify tests, measurements, observations, survey items, and clinical questions in a standardized way. It is associated with the component Blood group antibody. It is commonly used with the system or sample type Ser/Plas.
When is it used?
- Used in lab systems, EHRs, and clinical data exchange.
- May identify a test, observation, survey item, or clinical document request rather than a diagnosis.
- Status: ACTIVE
- Order vs observation: Both
- Method: Blood group antibody screen.LISS
What it does not mean
- The code identifies the observation or test, not the actual result.
Key facts
- Blood group antibody screen [Presence] in Serum or Plasma by Low ionic strength saline (LISS)
- Blood group antibody
- Antibody screening is used to demonstrate unexpected antibodies (other than ABO) and is performed on both donors and recipients to help ensure compatibility between recipient antibodies and donor red cells. Low ionic strength saline (LISS) is a blood banking potentiating agent that works by decreasing the repelling charges between red cells (zeta potential), thus packing the reds cells closer together for increased antibody bridging. This then decreases the incubation time for the sensitization phase in the antibody screening. A downside to using LISS is that it enhances the expression of cold antibodies and auto-antibodies that may not be significant. In addition, the ratio of serum to red cells must be adhered to strictly to maintain the ionic strength of the mixture. If ionic strength is too high, false negatives may occur, and if it is too low, false positives due to complement binding may occur.
- Ab; Bld gp Ab Scn; BLOOD BANK; Low ionic strength saline; Ordinal; Pl; Plasma; Plsm; Point in time; PR; QL; Qual; Qualitative; Random; Scn; Scr; Screen; Scrn; SerP; SerPl; SerPlas; Serum; Serum or plasma; SR
Where you may see this code
You may see this code in lab systems, lab reports, EHR exports, interoperability feeds, or other structured clinical data exchanges.
Related SNOMED CT concepts
Related observations and tests
Common synonyms
Frequently asked questions
About this content
This page is prepared by HealthAssure's clinical team using official coding standards from LOINC. AI tools assist with drafting explanations, which are then reviewed and verified by healthcare professionals for accuracy. This content is for informational purposes and does not replace professional medical advice. Meet our team.