LOINC Code 80619-0: ZIKV IgM IA Qn

80619-0 is a LOINC code used to identify ZIKV IgM IA Qn in laboratory and clinical observation data. You may see this code in lab systems, lab reports, EHR exports, interoperability feeds, or other structured clinical data exchanges. LOINC codes identify tests, measurements, observations, survey items, and clinical questions in a standardized way. It is associated with the component Zika virus Ab.IgM. It is commonly used with the system or sample type Ser/Plas.

Reviewed by HealthAssure Clinical TeamUpdated 21 May 2026

What is this code?

LOINC codes identify tests, measurements, observations, survey items, and clinical questions in a standardized way. It is associated with the component Zika virus Ab.IgM. It is commonly used with the system or sample type Ser/Plas.

When is it used?

  • Used in lab systems, EHRs, and clinical data exchange.
  • May identify a test, observation, survey item, or clinical document request rather than a diagnosis.
  • Status: ACTIVE
  • Order vs observation: Both
  • Method: IA

What it does not mean

  • The code identifies the observation or test, not the actual result.

Key facts

Zika virus IgM Ab [Units/volume] in Serum or Plasma by Immunoassay
Zika virus Ab.IgM
Quantitative analysis of Zika virus IgM antibodies in serum or plasma specimens by immunoassay-based methods. Similar to most EIA tests, results are reported as a ratio of optical densities. Zika virus IgM antibodies become detectable 4-8 days after the onset of symptoms and persist for months. Serological cross-reactivity is strong between Zika and other flaviviruses, especially Dengue virus. Therefore, positive results for this test are presumptive and should be confirmed by neutralizing antibody testing [LOINC80620-8]. Negative results for this test on a sample taken during the first week of illness does not rule out infection and the test should be repeated on a convalescent sample.
ABS; Aby; Antby; Anti; Antibodies; Antibody; Arbitrary concentration; Autoantibodies; Autoantibody; EIA; ELFA; ELISA; Enzyme immunoassay; IAA; ID; Immune globulin M; Immunoglobulin M; Infectious Disease; InfectiousDisease; MEIA; Microbiology; Pl; Plasma; Plsm; Point in time; QNT; Quan; Quant; Quantitative; Random; SerP; SerPl; SerPlas; Serum; Serum or plasma; SR; SUDS; ZIKV

Where you may see this code

You may see this code in lab systems, lab reports, EHR exports, interoperability feeds, or other structured clinical data exchanges.

Common synonyms

ZIKV IgM IA QnZika virus IgM Ab [Units/volume] in Serum or Plasma by ImmunoassayZIKV IgM SerPl IA-aCncZika virus Ab.IgMMICROZika virus IgM antibody, BloodACnc

Frequently asked questions

Code details

Code80619-0
SystemLOINC
Display nameZIKV IgM IA Qn
DescriptionZika virus Ab.IgM
Short nameZIKV IgM SerPl IA-aCnc
ComponentZika virus Ab.IgM
PropertyACnc
TimingPt
System (specimen)Ser/Plas
ScaleQn
MethodIA
ClassMICRO
Example unitsEIA index
StatusACTIVE
Order/ObservationBoth

Flags

BillableNo
Valid clinical useNo

Source

SourceLOINC
Version2.82
Releasemain
First released2.56
Last changed2.73

Consumer names

Zika virus IgM antibody, Blood

Part names

Zika virus Ab.IgMACncPtSer/PlasQnIAZika virus IgMArbitrary ConcentrationPoint in time (spot)Serum or PlasmaImmunoassay

About this content

This page is prepared by HealthAssure's clinical team using official coding standards from LOINC. AI tools assist with drafting explanations, which are then reviewed and verified by healthcare professionals for accuracy. This content is for informational purposes and does not replace professional medical advice. Meet our team.